Family house with 25 kW heat pump system

The heat and cool demand of this familiy house are 25 and 13 kW, so an IVT heat pump was installed with 25 kW nominal performance.

 

This heat pump supplies the domestic hot water demand, too and it has a weather-dependent regulator.
There is 500 m total BHE length on the primary side of this system. The pipes are single BHE with 40 mm diameter and the primary side is filled with ethylene glycol and water. The grouting material is bentonite-cement. This system utilized 20 kW geothermal heat.
The free-cooling is done by heat exchanger on the primary side. The heat pump makes domestic hot water in a 300-liter combined tank.
According to the plan this heat pump system was installed by the HGD Ltd.

The owner gained financial support for the heat pump system installation in 2008.

Angewandte Technologie: 
Wärmepumpe-System mit Erdwärmekollektoren
Stadt: 
Budapest XII
Heizungsleistung: 
25 kW
Kühlungsleistung: 
13 kW